6A 12/24VDC Power board 230V input
Utgang for lading av backup batteri
Input
Nominal 220VAC (range 198VAC-256VAC), 50/60Hz, 1.5A.
Input fuse rated @ 5A/250V.
Output
12VDC or 24VDC selectable output.
6A continuous supply current.
Filtered and electronically regulated output.
Short circuit and thermal overload protection.
Battery Charging
Built-in charger for sealed lead acid or gel type batteries.
Automatic switch over to stand-by battery when AC fails.
Zero voltage drop when switched over to battery backup.
(Batteries are sold separately).
Supervision
AC fail supervision (form "C" contacts).
Notification trigger is selectable for 30 seconds (factory set) or 6 hours.
Low battery supervision (form "C" contacts).
Battery presence supervision (form "C" contacts).
Visual Indicators
AC input, DC output and BAT trouble.
Electrical
Temperature:
Operating: 0° C to 49° C (32° F to 120° F).
Storage: - 20° C to 70° C ( - 4° F to 158° F).
Relative Humidity: 85% +/- 5%.
BTU/Hr. (approx.):
12VDC: 37 BTU/Hr.
24VDC: 74 BTU/Hr.
System AC input VA requirement: 330VA.
Tilbehør
Alternativer
Artikler
Antall artikler funnet:
Kundesenter
Sitemap
Kontakt Oss
Logg inn
Ingen varer i handlevognen
Ingen varer i ordreboka
produkt
produkter
(
)
(
)
(
)
Til kassen
×
Aktiv leveringsdato
Leveringsdatoer
Handlevogn
varer i handlevognen
Klikk her for å se alle
Handlevognen er tom.
Søk
Her er du nå:
Vicon Norway
>
PRODUKTER
>
Adgangskontroll
>
Diverse
>
6A 12/24VDC Power board 230V input
6A 12/24VDC Power board 230V input
Utgang for lading av backup batteri
Varenr:
AL600XB220
Beskrivelse
Support
Input
Nominal 220VAC (range 198VAC-256VAC), 50/60Hz, 1.5A.
Input fuse rated @ 5A/250V.
Output
12VDC or 24VDC selectable output.
6A continuous supply current.
Filtered and electronically regulated output.
Short circuit and thermal overload protection.
Battery Charging
Built-in charger for sealed lead acid or gel type batteries.
Automatic switch over to stand-by battery when AC fails.
Zero voltage drop when switched over to battery backup.
(Batteries are sold separately).
Supervision
AC fail supervision (form "C" contacts).
Notification trigger is selectable for 30 seconds (factory set) or 6 hours.
Low battery supervision (form "C" contacts).
Battery presence supervision (form "C" contacts).
Visual Indicators
AC input, DC output and BAT trouble.
Electrical
Temperature:
Operating: 0° C to 49° C (32° F to 120° F).
Storage: - 20° C to 70° C ( - 4° F to 158° F).
Relative Humidity: 85% +/- 5%.
BTU/Hr. (approx.):
12VDC: 37 BTU/Hr.
24VDC: 74 BTU/Hr.